summaryrefslogtreecommitdiff
path: root/lain/widgets/contrib/tpbat
diff options
context:
space:
mode:
Diffstat (limited to 'lain/widgets/contrib/tpbat')
-rw-r--r--lain/widgets/contrib/tpbat/init.lua170
-rw-r--r--lain/widgets/contrib/tpbat/smapi.lua102
2 files changed, 0 insertions, 272 deletions
diff --git a/lain/widgets/contrib/tpbat/init.lua b/lain/widgets/contrib/tpbat/init.lua
deleted file mode 100644
index 782bf35..0000000
--- a/lain/widgets/contrib/tpbat/init.lua
+++ /dev/null
@@ -1,170 +0,0 @@
-
---[[
-
- tpbat.lua
- Battery status widget for ThinkPad laptops that use SMAPI
- lain.widgets.contrib.tpbat
-
- More on tp_smapi: http://www.thinkwiki.org/wiki/Tp_smapi
-
- Licensed under GNU General Public License v2
- * (c) 2013, Conor Heine
- * (c) 2013, Luke Bonham
- * (c) 2010-2012, Peter Hofmann
-
---]]
-
-local debug = { getinfo = debug.getinfo }
-local newtimer = require("lain.helpers").newtimer
-local first_line = require("lain.helpers").first_line
-local beautiful = require("beautiful")
-local naughty = require("naughty")
-local wibox = require("wibox")
-
-local string = { format = string.format }
-local math = { floor = math.floor }
-local tostring = tostring
-local setmetatable = setmetatable
-
-package.path = debug.getinfo(1,"S").source:match[[^@?(.*[\/])[^\/]-$]] .. "?.lua;" .. package.path
-local smapi = require("smapi")
-
--- ThinkPad SMAPI-enabled battery info widget
--- lain.widgets.contrib.tpbat
-local tpbat = { }
-local tpbat_notification = nil
-
-function tpbat:hide()
- if tpbat_notification ~= nil
- then
- naughty.destroy(tpbat_notification)
- tpbat_notification = nil
- end
-end
-
-function tpbat:show(t_out)
- tpbat:hide()
-
- local bat = self.bat
- local t_out = t_out or 0
-
- if bat == nil or not bat:installed() then return end
-
- local mfgr = bat:get('manufacturer') or "no_mfgr"
- local model = bat:get('model') or "no_model"
- local chem = bat:get('chemistry') or "no_chem"
- local status = bat:get('state') or "nil"
- local time = bat:remaining_time()
- local msg = "\t"
-
- if status ~= "idle" and status ~= "nil"
- then
- if time == "N/A"
- then
- msg = "...Calculating time remaining..."
- else
- msg = time .. (status == "charging" and " until charged" or " remaining")
- end
- else
- msg = "On AC Power"
- end
-
- local str = string.format("%s : %s %s (%s)\n", bat.name, mfgr, model, chem)
- .. string.format("\n%s \t\t\t %s", status:upper(), msg)
-
- tpbat_notification = naughty.notify({
- preset = { fg = beautiful.fg_normal },
- text = str,
- timeout = t_out,
- screen = client.focus and client.focus.screen or 1
- })
-end
-
-function tpbat.register(args)
- local args = args or {}
- local timeout = args.timeout or 30
- local battery = args.battery or "BAT0"
- local settings = args.settings or function() end
-
- tpbat.bat = smapi:battery(battery) -- Create a new battery
- local bat = tpbat.bat
-
- tpbat.widget = wibox.widget.textbox('')
-
- bat_notification_low_preset = {
- title = "Battery low",
- text = "Plug the cable!",
- timeout = 15,
- fg = "#202020",
- bg = "#CDCDCD"
- }
-
- bat_notification_critical_preset = {
- title = "Battery exhausted",
- text = "Shutdown imminent",
- timeout = 15,
- fg = "#000000",
- bg = "#FFFFFF"
- }
-
- if bat:get('state') == nil
- then
- local n = naughty.notify({
- preset = bat_notification_low_preset,
- title = "SMAPI Battery Warning: Unable to read battery state!",
- text = "This widget is intended for ThinkPads. Is tp_smapi installed? Check your configs & paths.",
- screen = client.focus and client.focus.screen or 1
- })
- end
-
- function update()
- bat_now = {
- status = "Not present",
- perc = "N/A",
- time = "N/A",
- watt = "N/A"
- }
-
- if bat:installed()
- then
- bat_now.status = bat:status() or "N/A"
- bat_now.perc = bat:percent()
- bat_now.time = bat:remaining_time()
- -- bat_now.watt = string.format("%.2fW", (VOLTS * AMPS) / 1e12)
-
- -- notifications for low and critical states (when discharging)
- if bat_now.status == "discharging"
- then
- if bat_now.perc <= 5
- then
- tpbat.id = naughty.notify({
- preset = bat_notification_critical_preset,
- replaces_id = tpbat.id,
- screen = client.focus and client.focus.screen or 1
- }).id
- elseif bat_now.perc <= 15
- then
- tpbat.id = naughty.notify({
- preset = bat_notification_low_preset,
- replaces_id = tpbat.id,
- screen = client.focus and client.focus.screen or 1
- }).id
- end
- end
-
- bat_now.perc = tostring(bat_now.perc)
- end
-
- widget = tpbat.widget
- settings()
- end
-
- newtimer("tpbat", timeout, update)
-
- widget:connect_signal('mouse::enter', function () tpbat:show() end)
- widget:connect_signal('mouse::leave', function () tpbat:hide() end)
-
- return tpbat.widget
-end
-
-return setmetatable(tpbat, { __call = function(_, ...) return tpbat.register(...) end })
diff --git a/lain/widgets/contrib/tpbat/smapi.lua b/lain/widgets/contrib/tpbat/smapi.lua
deleted file mode 100644
index c7f093e..0000000
--- a/lain/widgets/contrib/tpbat/smapi.lua
+++ /dev/null
@@ -1,102 +0,0 @@
-
---[[
-
- smapi.lua
- Interface with thinkpad battery information
-
- Licensed under GNU General Public License v2
- * (c) 2013, Conor Heine
-
---]]
-
-local first_line = require("lain.helpers").first_line
-
-local string = { format = string.format }
-local tonumber = tonumber
-local setmetatable = setmetatable
-
-local smapi = {}
-
-local apipath = "/sys/devices/platform/smapi"
-
--- Most are readable values, but some can be written to (not implemented, yet?)
-local readable = {
- barcoding = true,
- charging_max_current = true,
- charging_max_voltage = true,
- chemistry = true,
- current_avg = true,
- current_now = true,
- cycle_count = true,
- design_capacity = true,
- design_voltage = true,
- dump = true,
- first_use_date = true,
- force_discharge = false,
- group0_voltage = true,
- group1_voltage = true,
- group2_voltage = true,
- group3_voltage = true,
- inhibit_charge_minutes = false,
- installed = true,
- last_full_capacity = true,
- manufacture_date = true,
- manufacturer = true,
- model = true,
- power_avg = true,
- power_now = true,
- remaining_capacity = true,
- remaining_charging_time = true,
- remaining_percent = true,
- remaining_percent_error = true,
- remaining_running_time = true,
- remaining_running_time_now = true,
- serial = true,
- start_charge_thresh = false,
- state = true,
- stop_charge_thresh = false,
- temperature = true,
- voltage = true,
-}
-
-function smapi:battery(name)
- local bat = {}
-
- bat.name = name
- bat.path = apipath .. "/" .. name
-
- function bat:get(item)
- return self.path ~= nil and readable[item] and first_line(self.path .. "/" .. item) or nil
- end
-
- function bat:installed()
- return self:get("installed") == "1"
- end
-
- function bat:status()
- return self:get('state')
- end
-
- -- Remaining time can either be time until battery dies or time until charging completes
- function bat:remaining_time()
- local time_val = bat_now.status == 'discharging' and 'remaining_running_time' or 'remaining_charging_time'
- local mins_left = self:get(time_val)
-
- if mins_left:find("^%d+") == nil
- then
- return "N/A"
- end
-
- local hrs = math.floor(mins_left / 60)
- local min = mins_left % 60
- return string.format("%02d:%02d", hrs, min)
- end
-
- function bat:percent()
- return tonumber(self:get("remaining_percent"))
- end
-
- return setmetatable(bat, {__metatable = false, __newindex = false})
-end
-
-return smapi